Transformer Winding Resistance Meters

       

Transformer Winding Resistance Meter

 
       
View Full Specs

The TRM-40 is Vanguard Instruments’ third generation transformer winding resistance meter. The TRM-40 is designed specifically to measure DC resistance values of transformer windings, rotating machine windings, or any dc resistance of an inductive device.

  • Auto-discharge circuit for operator safety
  • Demagnetizes transformer after test
  • Selectable test current from 1A to 40A
  • RS-232C, USB, and Bluetooth computer interfaces
  • Built-in thermal printer
       

Transformer Winding Resistance Meter

 
       
View Full Specs

The TRM-20 is Vanguard Instruments’ third generation transformer winding resistance meter. The TRM-20 is designed specifically to measure DC resistance values of transformer windings, rotating machine windings, or any dc resistance of an inductive device.

  • Auto-discharge circuit for operator safety
  • Demagnetizes transformer after test
  • Selectable test current from 1A to 25A
  • RS-232C, USB, and Bluetooth computer interfaces
  • Built-in thermal printer
       

Transformer Resistance Meter

 
       
View Full Specs

The TRM-203 is a  three phase transformer winding resistance meter that allows the user to connect all test cables to the transformer bushings. The unit will then measure the transformer resistance value for each of the phases without the need to disconnect and reconnect cables for each phase. The TRM-203 can provide a fast and stable reading of very large transformers by utilizing a 60Vdc power supply. It is capable of outputting a selectable test current from 1A to 25A.

  • Perform three phase test on a transformer without the need to switch cables
  • Can provide individual Delta winding resistance values
  • Can provide individual Wye (with no neutral) winding resistance values
  • Demagnetize transformer after test
  • Selectable test current from 1A to 25A
  • Computer control via RS-232C, USB, or Bluetooth interface
  • Built-in 2.5" wide thermal printer
       

Transformer Resistance Meter

 
       
View Full Specs

The TRM-403 is a  three phase transformer winding resistance meter that allow the user to connect all test cables to the transformer bushings. The unit will then measure the transformer resistance value for each of the phases without the need to disconnect and reconnect cables for each phase. The TRM-403 can provide a fast and stable reading of very large transformers by utilizing a 60Vdc power supply. It is capable of outputting a selectable test current from 1A to 40A.

  • Perform three phase test on a transformer without the need to switch cables
  • Can provide individual Delta winding resistance values
  • Can provide individual Wye (with no neutral) winding resistance values
  • Demagnetize transformer after test
  • Selectable test current from 1A to 40A
  • Computer control via RS-232C, USB, or Bluetooth interface
  • Built-in 2.5" wide thermal printer
       

TSB

Trip Saver Box

 
       
View Full Specs

The Vanguard TSB can be used with a Vanguard ATRT-03 series turns ratio tester to perform transformer turns ratio tests using the same cable set provided with the TRM-203/403. Using the TSB, there is no need to connect and reconnect cables from the transformer after the initial connections are made. The user can conveniently perform resistance tests using the TRM-203/403 and turns ratio tests using an ATRT-03 without having to make trips to the transformer to connect and disconnect cables.

       

Load Tap Changer Analyzer

 
       
View Full Specs

The LTCA-10 Analyzer is a second generation load tap changer analyzer. The LTCA-10 accurately measures winding resistance of highly inductive power transformers. Triple resistance-reading channels allow the measurement of three winding resistances simultaneously. Four-wire (Kelvin) connections provide high accuracy and require no lead compensation. A special feature of this device is its ability to measure and graph the resistance trace of a transformer LTC during operation. Using a 60Vdc power supply, the LTCA-10 is capable of outputting 10 amperes.

  • Auto discharge circuit for operator safety
  • 3 resistance reading channels including one dynamic channel
  • Digital resistance reading from 1 micro-ohm to 500 ohms
  • Calculate equivalent resistance value at reference temperature
  • Stores 50 static records and 20 dynamic records
  • Built-in 4.5-inch thermal printer
  • Weighs less than 44 lbs.
       

Load Tap Changer Analyzer

 
       
View Full Specs

The LTCA-40 Analyzer is a second generation load tap changer analyzer. The LTCA-40 accurately measures winding resistance of highly inductive power transformers. Triple resistance-reading channels allow the measurement of three winding resistances simultaneously. Four-wire (Kelvin) connections provide high accuracy and require no lead compensation. A special feature of this device is its ability to measure and graph the resistance trace of a transformer LTC during operation. Using a 60Vdc power supply, the LTCA-40 is capable of outputting 40 amperes.

  • Auto discharge circuit for operator safety
  • 3 resistance reading channels including one dynamic channel
  • Digital resistance reading from 1 micro-ohm to 500 ohms
  • Calculate equivalent resistance value at reference temperature
  • Stores 50 static records and 20 dynamic records
  • Built-in 4.5-inch thermal printer
  • Weighs less than 44 lbs.
       

Winding Resistance Ohmmeter

 
       
View Full Specs

The WRM-10P S2 is Vanguard's second generation lightweight winding resistance meter designed to accurately measure the winding resistance of highly inductive power transformers. The unit’s dual resistance-reading input channels can measure two winding resistances simultaneously, and four-wire (Kelvin) connections provide high accuracy and require no lead compensation. The WRM-10P S2 provides stable resistance readings of very large transformers by utilizing a 36Vdc power supply capable of outputting up to 10 Amperes.

  • Auto discharge circuit for operator safety
  • Auto current ranging from 10 mA to 10 A
  • Digital resistance reading from 1 micro-ohm to 2,000 ohms
  • Stores 100 records (up to 64 readings each)
  • Built in 2.5" wide thermal printer
  • Weighs less than 28 lbs.
       

Field Pictures

   
       
TNB ATRT/WRM Training and Delivery
TRM-203 in Malaysia
TRM-203 Testing on 200MVA Transformer
TRM-403 Testing at Elecktromak, Turkey
TRM-403 Testing in Malaysia
TRM-403 at CFE Tizayuca Substation - Mexico
TRM-403 at CFE Tizayuca Substation - Mexico
LTCA-40 at BSES Substation in New Delhi, India
TRM-203 Testing Transformer at PLN Balikpapan Substation, Indonesia